Goniophotometer sind Hilfsmittel zur Beurteilung des Lichtstroms, auch bekannt als Helligkeit verschiedener Gerätetypen. Ein Goniophotometer LM-79 LM mit beweglichem Detektor sammelt photometrische Daten von verschiedenen kugelförmigen Orten. Es hilft dann, die Qualität der zu verkaufenden Waren sicherzustellen. Es unterstützt auch die Marktstellung des Verkäufers oder des Herstellers. Die Hauptanwendung des Geräts ist die Messung des Lichtstroms fokussierter Lichtquellen.
These include LEDs, lamps, and automobile headlights. The photometric measurements made in this instance and the part played by the available manufacturers are crucial. This article will discuss what the type C goniophotometer is, its use, and its functionality in addition to briefly discussing LISUN as one of the best producers of goniophotometers.
LM-79 Beweglicher Detektor Goniophotometer | Spiegel Typ C | LSG-6000
In complete compliance with LM-79-19, IES LM-80-08, commission delegated regulation (EU) 2019/2015, CIE-121, CIE S025, SASO 2902, IS16106, and EN13032-1 clause 6.1.1.3 type 4 requirements is provided by the LISUN LSG-6000 Moving Detector Goniophotometer (Mirror Type C). The LSG-6000 is a 3D curve testing system. It is use for testing automatic light distribution intensity that complies with Clause 7.3.1 of the LM-79-19 standard and is the most recent improved version of the LSG-5000 and LSG-3000. The measuring range is 5 to 30 meters.
Goniophotometer LSG-6000
Gonio-Photometrie bezieht sich auf das Verfahren zur Messung der Winkelverteilung von Licht. Der Begriff „Goniophotometer“ bezieht sich auf ein photometrisches Werkzeug, das ein Photometer und einen goniometrischen Bewegungstisch kombiniert, um das von einem Objekt in verschiedenen Winkeln emittierte Licht zu messen. In sehr einfachen Worten handelt es sich also um ein Gerät zur LED-Messung.
Es ist allgemein bekannt, dass LISUN produces many goniophotometer models in line with CIE, IEC, and other local, national, and worldwide standards.
A Goniophotometer Typ C ist ein optisches Werkzeug, das verwendet wird, um die Lichtmenge zu messen, die an verschiedenen Stellen in einem einzigen Bereich vorhanden ist. Es wird verwendet, um die Leistung und Wirksamkeit verschiedener Arten von Lichtquellen zu messen, indem deren Betrieb und Helligkeit getestet werden. Das Goniophotometer wird typischerweise an Orten mit einer einzigen Lichtquelle verwendet. Die Stärke und Intensität der unidirektionalen Lichtquelle werden mit einem Goniophotometer gemessen. Dabei wird sowohl die Temperatur als auch die Konsistenz der Farbe im Streulicht geprüft.
Unter Berücksichtigung des oben Beschriebenen lassen sich die Einsatzmöglichkeiten des Goniophotometers wie folgt zusammenfassen:
Im Vergleich zu anderen Goniophotometer Arten, der C-Typ ist einzigartig. Bewegliches Detektor-Goniophotometer ist ein anderer Name für das LSG-6000 Goniophotometer. Von allen Typ-C-Goniophotometern ist das IES Testing LSG 6000 Typ-C-Goniophotometer das neueste Modell. Es hat besondere Qualitäten. Dieses Instrument hat einen Messbereich von 5 bis 30 Metern. Diese optische Vorrichtung, der Nahfelddetektor und der Hauptspiegel, bewegen sich beide gemeinsam in die gleiche Richtung. Dieses Instrument ist aufgrund seiner hohen Qualität das genaueste und modernste seiner Art. Bestimmte Funktionen des Geräts umfassen:
Bestimmte Produktspezifikationen der Typ-C-Goniophotometer sind
Wie funktionieren Goniophotometer vom Typ C?
Das Goniophotometer LM-79 mit beweglichem Detektor verwendet ein rotierendes Licht und einen statischen Detektor, um zu messen, wie intensiv das Licht um die Lichtquelle oder das Licht verteilt ist. Der Laserstrahl des Laservisiers behält die Ausrichtung zwischen dem Leuchtzentrum des Messlichts und dem Drehzentrum des zweidimensionalen rotierenden Arbeitstisches bei, wenn das Licht auf dem Arbeitstisch montiert ist. Der Detektor, der auf der gleichen Höhe wie die Mitte des rotierenden Arbeitstisches positioniert ist, erfasst die Lichtintensitätswerte in allen Richtungen auf der horizontalen Ebene, während sich das Licht um die vertikale Achse dreht.
LM-79 Beweglicher Detektor Goniophotometer LSG-6000
Der Detektor überwacht die Lichtintensität auf der vertikalen Ebene in allen Richtungen, während sich das Licht um die horizontale Achse dreht. Sowohl die vertikale als auch die horizontale Achse können stufenlos zwischen 180 und 360 Grad gedreht werden. Der Computer bestimmt mehrere Helligkeitsparameter und Lichtverteilungskurven, nachdem er die Daten über die Lichtintensitätsverteilung der Lichter in allen Richtungen gemäß den Messlichtern erfasst hat. Das Goniophotometer wird typischerweise an Orten mit einer einzigen Lichtquelle verwendet.
Die Stärke und Intensität der unidirektionalen Lichtquelle werden mit einem Goniophotometer gemessen. Dabei wird sowohl die Temperatur als auch die Konsistenz der Farbe im Streulicht geprüft. Zusammenfassend lässt sich aus der obigen Diskussion schließen, dass ein Goniophotometer verwendet wird, um die Lichtmenge zu messen, die von einer Lichtquelle unter verschiedenen Winkeln emittiert wird. Es bestimmt die Farbe und Textur des gestreuten Lichts, und es werden die Eigenschaften der unidirektionalen Lichtquelle sowie die Temperatur des gestreuten Lichts gemessen.
Wofür wird ein LM-79-Goniophotometer mit beweglichem Detektor verwendet?
One of the most well-known producers of goniophotometers is LISUN. The LSG-6000 goniophotometer is specifically designed to evaluate the luminous flux of directed light sources like LEDs and automobile headlights, as was previously mentioned. It is a photometric tool for measuring how strong a light source appears from different perspectives. A goniophotometer serves a variety of functions. Automated systems for testing automotive lights are one of its most popular uses.
It establishes the intensity of a vehicle’s light. It is crucial to keep in mind when utilizing LISUN’s goniophotometers that directed light sources are typically used with it. This suggests that unidirectional light measurements conducted with such a meter will produce more precise findings. The gadget can also be used to check the uniformity of color and temperature. This attribute can be of use if the equipment incorporates color sensors.
Gonio-Spektrometer
Die Leuchte, die von einem herkömmlichen Goniophotometer gemessen wird, wird von einem mechanischen oder Roboterausleger getragen. Es hat auch ein Photometer oder Spektrometer, das es ermöglicht, den Abstand zwischen den Leuchten einzustellen, um einen sphärischen Ort zu erzeugen.
Entscheidend ist die Analyse der optischen Daten des Spektrums Abstrahlwinkel. Dies liegt daran, dass es die Bestimmung von Farbmengen, spektralem Strahlungsstrom und Gesamtlichtstrom ermöglicht. Es ermöglicht die Erkennung der tatsächlichen Farbe des Materials. Bei vom Benutzer wählbaren Beleuchtungs- und Erfassungswinkeln unterstützt es auch die räumliche Verteilung von reflektiertem (oder durchgelassenem) Licht.
Häufig gestellte Fragen (FAQs)
Welche Schritte müssen unternommen werden, um das LSG-6000 Goniophotometer zu installieren?
One of the best and most reputable companies, LISUN, sends its engineers to install the gadget. In addition to correctly installing the gadget, these experts make sure it is operating properly and assist the customer as much as possible.
Können Daten vom Goniophotometer an Großrechner und andere Geräte gesendet werden?
The goniophotometer can be connected to a computer via a USB cable. English-language software is compatible with Windows 7, Windows 8, Windows 10, and Windows 11. Additionally, the CIE, IES, LDT, and other file formats are supported for export by the LISUN goniophotometer program. These format files can be used by other applications for designing luminaires and lighting.
Wie funktioniert das Spiegelgoniophotometer?
Das Goniophotometer verwendet einen festen Detektor und einen rotierenden Lichtansatz für die Messung. Die Messlampe ist auf einem zweidimensional drehbaren Arbeitstisch montiert, und der Laserstrahl des Laservisiers richtet das Leuchtzentrum der Lampe mit dem Rotationszentrum des sich drehenden Arbeitstisches aus.
Wie kann eine LED-Deckenleuchte mit einem Goniophotometer getestet werden?
Das Leuchtdichte-Integrationsverfahren und das Lichtintensitäts-Integrationsverfahren sind zwei Messschemata, die verwendet werden können, um den Lichtstrom in Abhängigkeit von der Messung verschiedener optischer Weganordnungen zu messen. Das integrale Beleuchtungsverfahren Der Messabstand ist nach oben unbegrenzt und es wird nur wenig Platz benötigt. Der genaue Gesamtlichtstrom kann bestimmt werden, solange die Beleuchtungsstärke auch im Nahbereich messbar ist.
Sie kann mit einem kleinen, verteilten Photometer gemessen werden, das den gesamten Lichtstrom über den gesamten Raum integriert und die Beleuchtungsstärkeverteilung der Lichtquelle im Raum misst. Die CIE empfiehlt, den Ansatz zur Ermittlung von Lichtstrom-Referenzeinheiten zu verwenden, da er hochgenaue Messungen ermöglicht und gleichzeitig unempfindlich gegenüber dem Messabstand und dem Installationsort der Lichtquelle ist.
Integration der Lichtintensität
Die Lichtstärkeintegrationsmethode integriert den gesamten Lichtstrom über den gesamten Raum, während die Lichtstärkeverteilung der Lichtquelle im Raum gemessen wird. Der Abstand, der benötigt wird, um den Analyten als Punktlichtquelle anzunähern und die Lichtintensität unter Verwendung des inversen quadratischen Verhältnisses des Abstands zu messen, wird benötigt, um die Lichtintensitätsdispersion zu messen.
Lisun Instruments Limited wurde gefunden von LISUN GROUP von Studenten unterstützt. LISUN Das Qualitätssystem wurde streng nach ISO9001:2015 zertifiziert. Als CIE-Mitgliedschaft LISUN Die Produkte werden auf der Grundlage von CIE, IEC und anderen internationalen oder nationalen Standards entwickelt. Alle Produkte haben das CE-Zertifikat bestanden und wurden vom Drittlabor authentifiziert.
Unsere Hauptprodukte sind Goniophotometer, Sphere integrieren, Spektralradiometer, Überspannungsgenerator, ESD-Simulatorpistolen, EMI-Empfänger, EMV-Testgeräte, Elektrischer Sicherheitstester, Klimakammer, Temperaturkammer, Klimakammer, Wärmekammer, Salzsprühtest, Staubprüfkammer, Wasserdichter Test, RoHS-Test (EDXRF), Glühdrahttest funktioniert Nadelflammtest.
Bitte zögern Sie nicht, uns zu kontaktieren, wenn Sie Unterstützung benötigen.
Technische Abteilung: Service@Lisungroup.com , Cell / WhatsApp: +8615317907381
Verkaufsabteilung: Sales@Lisungroup.com , Cell / WhatsApp: +8618117273997
Deine Email-Adresse wird nicht veröffentlicht. Erforderliche Felder sind markiert *